EI DU PONT DE NEMOURS & CO -- FREON 12 -- 6830-01-382-1501
===================== Product Identification =====================
Product ID:FREON 12
MSDS Date:12/01/1992
FSC:6830
NIIN:01-382-1501
=== Responsible Party ===
Company Name:EI DU PONT DE NEMOURS & CO
Address:1007 MARKET ST
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-9442
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
CAGE:FO317
=== Contractor Identification ===
Company Name:DU PONT E I DE NEMOURS & CO INC IMAGING SYS DEPT
Address:BARLEY MILL PLZ 22-1356
Box:80022
City:WILMINGTON
State:DE
ZIP:19880-0022
Country:US
Phone:302-992-2012
CAGE:82348
Company Name:EI DU PONT DE NEMOURS CO/AUTO PROD DEPT
City:WILMINGTON
State:DE
ZIP:19898
Phone:(800) 441-7515
CAGE:FO317
============= Composition/Information on Ingredients =============
Ingred Name:METHANE, DICHLORODIFLUORO-; (FREON 12) (SARA 313) (CERCLA)
CAS:75-71-8
RTECS #:PA8200000
Fraction by Wt: 100%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1
Ingred Name:SUPDAT: DIZZ, HDCH, CONFUSION, INCOORD & LOSS OF
CONSCIOUSNESS; TEMPORARY ALTERATION OF HEART'S ELECTRICAL (ING 3)
RTECS #:9999999ZZ
Ingred Name:ING 2: ACTIVITY W/IRREGULAR PULSE, PALPITATION OR INADEQ
CIRCULATION OR EFTS OF EXCLUSION OF OXYGEN W/GROSSLY (ING 4)
RTECS #:9999999ZZ
Ingred Name:ING 3: EXCESSIVE EXPOSURES. INDIVIDUALS W/PREEXISTING
DISEASES OF CNS OR CVS MAY HAVE INCRD SUSCEPTIBILITY TO (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4: TOXICITY OF EXCESSIVE EXPOS. ANIMAL DATA: EFTS IN
ANIMALS FROM SINGLE HIGH EXPOS BY INHAL INCL ANESTHESIA (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5:& IRREGULAR HEARTBEAT (CARD ARRHYTHMIAS). RPTD INHAL
EXPOS PRDCED ALTERED RESP FUNCTION. LONG-TERM STUDIES (ING 7)
RTECS #:9999999ZZ
Ingred Name:ING 6: SHOWED NO SIGNIFICANT CLINICAL, BLOOD CHEM OR
PATHOLOGICAL EFTS FOLLOWING RPTD EXPOS. EFTS IN ANIMALS (ING 8)
RTECS #:9999999ZZ
Ingred Name:ING 7: FROM LONG-TERM INGEST OF THIS MATL INCL SLIGHT
ALTERATIONS IN BLOOD CHEMISTRY & BODY WEIGHT GAIN. NO (ING 9)
RTECS #:9999999ZZ
Ingred Name:ING 8: OTHER CLINICAL, BIOCHEMICAL OR PATHOLOGICAL SIGNS OF
TOXICITY HAVE BEEN OBSERVED.
RTECS #:9999999ZZ
Ingred Name:FIRST AID PROC: BECAUSE OF A POSS DISTURBANCE OF CARDIAC
RHYTHM, CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, (ING 11)
RTECS #:9999999ZZ
Ingred Name:ING 10: SHOULD ONLY BE USED W/SPECIAL CAUTION IN SITUATIONS
OF EMERGENCY LIFE SUPPORT.
RTECS #:9999999ZZ
Ingred Name:VENT: AMOUNTS ARE RELEASED. MECHANICAL VENTILATION SHOULD
BE USED IN LOW OR ENCLOSED PLACES.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50: (ORAL, RAT) >1,000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROFLUOROCARBON (CFC) MATLS HAVE
PRDCED SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS &
COULD HAVE A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (IE,
EPINEPHRINE) MAY BE CONTRA-INDICATED EXCE PT FOR LIFE-SUSTAINING
USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO CFCS . INHAL OF
HIGH (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: CONCS OF VAP IS HARMFUL & MAY CAUSE
HEART IRREGULARITIES, UNCON OR DEATH. INTENTIONAL MISUSE OR DELIB
INHAL MAY CAUSE DEATH W/OUT WARNING. VAP REDUCES OXYGEN AVAIL FOR
BRTHG & IS HVR/AIR. LI Q CONTACT CAN CAUSE FROSTBITE. MAY CAUSE EYE
IRRIT. HUMAN HLTH EFTS OF OVEREXP BY EYE CONTACT W/VAP MAY INCLUDE
(SUPDAT)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
DISEASES OF THE CENTRAL NERVOUS OR CARDIOVASCULAR SYSTEM MAY HAVE
INCREASED SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURES.
======================= First Aid Measures =======================
First Aid:INGEST: CALL MD IMMED . INHAL: IF HIGH CONCS ARE INHALED,
IMMED REMOVE TO FRESH AIR. KEEP PERSON CALM. IF NOT BRTHG, GIVE
ARTF RRESP. IF BRTHG IS DFCLT, GIVE OXYGEN. CALL MD. SKIN: IN CASE
OF CO NTACT, FLUSH SKIN W/WATER. TREAT FOR FROSTBITE IF NECESSARY
BY GENTLY WARMING AFFECTED AREA. EYES: IN CASE OF CONTACT, IMMED
FLUSH EYES W/PLENTY OF WATER FOR AT LEAST 15 MIN. CALL MD. (ING 10)
===================== Fire Fighting Measures =====================
Flash Point:WILL NOT BURN
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:WEAR NIOSH APPROVED PRESSURE DEMAND SCBA AND
FULL PROTECTIVE EQUIPMENT . USE WATER SPRAY OR FOG TO COOL
CONTAINERS.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE FLUORIDES, CHLORIDES AND PHOSGENE . CYLINDERS MAY RUPTURE
UNDER FIRE CONDITIONS. DECOMPOSITION MAY OCCUR.
================== Accidental Release Measures ==================
Spill Release Procedures:NOTE:REVIEW FIRE FIGHT MEASURES & HNDLG
SECTIONS BEFORE PROCEEDING W/CLEANUP. USE APPROP PERSONAL PROT
EQUIP DURING CLEANUP. VENT AREA, ESP LOW/ENCLSD PLACES WHERE HEAVY
VAPS MIGHT COLLECT. REMOVE OPE N FLAMES. USE NIOSH APPRVD SCBA FOR
LARGE SPILLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE W/SUFFICIENT VENTILATION TO KEEP
EMPLOYEE EXPOSURE BELOW RECOMMENDED LIMITS. STORE IN CLEAN, DRY
AREA. DO NOT HEAT ABOVE 52C (125F).
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES OR
PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS, NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT. NIOSH
APPROVED SELF-CONTAINED BREATHING APPARATUS (SCBA) IS REQUIRED IF A
LARGE RELEASE OCCURS.
Ventilation:NORMAL VENT FOR STANDARD MANUFACTURING PROCS IS GENERALLY
ADEQUATE. LOCAL EXHAUST SHOULD BE USED WHEN LARGE (ING 12)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP: 94.5 PSIA @ 25C. HAZ DECOMP PRODS: SURFS, ETC) FORMING HYDROCHLORIC
& HYDROFLUORIC ACIDS & POSSIBLY CARBONYL HALIDES. EFTS OF OVEREXP:
EYE IRRIT W/DISCOMFORT, TEARING OR BLURRING OF VISION. SKIN C NTCT
W/LIQ MAY CAUSE FROSTBITE. INHAL OF VAPS MAY CAUSE TEMPORARY
NERVOUS SYS DEPRESS W/ANESTH EFTS SUCH AS (ING 2)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:-22F,-30C
Vapor Pres:SUPDAT
Vapor Density:4.26
Spec Gravity:1.315
pH:NEUT
Solubility in Water:0.028 @ 25C AT 1 ATM
Appearance and Odor:LIQUIFIED GAS, CLEAR, COLORLESS; SLIGHT ETHEREAL
ODOR.
Percent Volatiles by Volume:100 WT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH ALKALI OR ALKALINE EARTH METALS - POWDERED AL, ZN,
BE, ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:PHOSGENE . DECOMP PRODS ARE HAZ. FREON
12 CAN BE DECOMPOSED BY HIGH TEMPS (OPEN FLAMES, GLOWING METAL
(SUPDAT)
==================== Disposal Considerations ====================
Waste Disposal Methods:COMPLY WITH FEDERAL, STATE AND LOCAL
REGULATIONS. RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE
FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.