THE WELLA CORP -- COLOR CHARM LIQUID CREME HAIR COLOR -- 8510-00D007082
===================== Product Identification =====================
Product ID:COLOR CHARM LIQUID CREME HAIR COLOR
MSDS Date:06/11/1991
FSC:8510
NIIN:00D007082
=== Responsible Party ===
Company Name:THE WELLA CORP
Address:524 GRAND AVE.
City:ENGLEWOOD
State:NJ
ZIP:07631
Country:US
Info Phone Num:201-569-1020
Emergency Phone Num:201-569-1020
CAGE:66740
=== Contractor Identification ===
Company Name:H.C. KUHLMAN CO
Address:5519-A PRIDE RD
City:RICHMOND
State:VA
ZIP:23224
Country:US
Phone:804-232-7811
CAGE:2E862
Company Name:THE WELLA CORP
Address:524 GRAND AVE.
Box:City:ENGLEWOOD
State:NJ
ZIP:07631
Country:US
Phone:201-569-1020
CAGE:66740
============= Composition/Information on Ingredients =============
Ingred Name:AMMONIA (SARA 302/313) (CERCLA)
CAS:7664-41-7
RTECS #:BO0875000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:50 PPM
ACGIH TLV:25 PPM/35 STEL; 9596
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:ISOPROPYL ALCOHOL (SARA 313)
CAS:67-63-0
RTECS #:NT8050000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:400 PPM
ACGIH TLV:400 PPM/500STEL;9596
Ingred Name:P-PHENYLENEDIAMINE (SARA 313) (CERCLA)
CAS:106-50-3
RTECS #:SS8050000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:S, 0.1 MG/M3
ACGIH TLV:0.1 MG/M3; 9596
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:RESORCINOL (CERCLA)
CAS:108-46-3
RTECS #:VG9625000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:10 PPM
ACGIH TLV:10 PPM/20 STEL; 9596
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50 ORAL RAT HAS NOT BEEN ESTABLISHED
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:**SENSITIZER** PARAPHENYLENEDIAMINE IS
A SENSITIZER(DERMAL).A 24-HOUR PATCH TEST OS REQUIRED BEFORE USING
THIS PRODUCT(FDA REGULATION).
Explanation of Carcinogenicity:THIS ITEM DOES NOT CONTAIN ANY
INGREDIENT AT 0.1% OR GREATER WHICH IS A CARCINOGEN.
Effects of Overexposure:SKIN:IRRITATION,REDNESS,DERMATITIS.
Medical Cond Aggravated by Exposure:MFR STATES NONE.
======================= First Aid Measures =======================
First Aid:EYES:FLUSH WITH WATER UNTIL ALL TRACES OF THIS MATERIAL ARE
GONE.SEEK MEDICAL ATTENTION IF IRRITATION PERSISTS.SKIN:REMOVE
CONTAMINATED CLOTHING.RINSE WITH WATER,THEN WASH WITH SOAP AND
WATER.SEEK MED ICAL ATTENTION IF IRRITATION PERSISTS.INHAL:REMOVE
FROM EXPOSURE.GIVE OXYGEN OR ARTIFICIAL RESPIRATION IF
NESCESSARY.INGEST:DO NOT INDUCE VOMITING.GET PROMPT QUALIFIED
MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:172F,78C
Extinguishing Media:WATER,WATER FOG,DRY CHEMICAL,CARBON DIOXIDE.
Fire Fighting Procedures:HMIS SUGGESTS USING A SELF-CONTAINED BREATHING
APPARATUS AND FULL FIRE PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:**COMBUSTIBLE**
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA.SOAK UP WITH AN
INERT,NON-COMBUSTIBLE ABSORBANT.WASH SPILL AREA.
Neutralizing Agent:NONE SPECIFIED BY MFR.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL-VENTILATED
PLACE.KEEP CONTAINER CLOSED WHEN NOT IN USE.AVOID HEAT,SPARKS AND
FLAMES.
Other Precautions:AVOID CONTAMINATION OF ANY KIND.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE SHOULD BE NESCESSARY UNDER NORMAL
CIRCUMSTANCES.
Ventilation:USE LOCAL EXHAUST AT THE WORKSITE;GENERAL EXHAUST TO
MAINTAIN TLV/PEL.
Protective Gloves:PLASTIC OR RUBBER.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:APRON.PROVIDE A LOCAL EYE WASH STATION.
Work Hygienic Practices:USE REASONABLE CARE WITH THIS ITEM.WASH HANDS
BEFORE EATING.
Supplemental Safety and Health
NONE
================== Physical/Chemical Properties ==================
HCC:T6
Spec Gravity:0.95
Solubility in Water:SOLUBLE
Appearance and Odor:CLEAR,YELLOW TO RED LIQUID,CHARACTERISTIC AMMONIA
ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
DO NOT USE METAL CONTAINERS FOR MIXING.
Stability Condition to Avoid:OPEN FLAME
Hazardous Decomposition Products:MFR STATES NONE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.